• HXGL-1
  • HXGL-2
  • HXGL-3

electrical heating steam boiler

Short Description:


Product Detail

Product Tags

Features

Safety
1.Leakage protection: When the boiler leaks, the power supply will be cut off in time through the leakage circuit breaker to ensure personal safety. 2.Water shortage protection: When the boiler is short of water, cut off the heating tube control circuit in time to prevent the heating tube from being damaged by dry burning. At the same time, the controller sends out a water shortage alarm. 3.Steam overpressure protection: When the boiler steam pressure exceeds the set upper limit pressure, the safety valve is activated to release the steam to reduce the pressure. 4.Over-current protection: When the boiler is overloaded (the voltage is too high), the leakage circuit breaker will automatically open. 5.Power protection: Reliable power-off protection is carried out after detecting over-voltage, under-voltage, and interruption fault conditions with the help of advanced electronic circuits.

Convenience
PLC microcomputer programmable control and display screen, through the man-machine interface to realize the temperature setting and automatic control of the outlet water temperature, the display screen can display the equipment running state and the machine failure alarm
Fully automatic intelligent control technology, no need to be on duty, flexible working mode, can be set to manual or automatic mode
It has a complete set of multiple protection functions, including leakage protection, water shortage protection, grounding protection, steam overpressure protection, power protection and other boiler automatic protection systems

Rationality
In order to use electric energy reasonably and effectively, the heating power is divided into several sections, and the controller automatically turns on (cuts off) the heating power according to actual needs. After the user determines the heating power according to actual needs, he only needs to close the corresponding leakage circuit breaker (or press the corresponding switch). Switch). The heating tube is switched on and off in stages, which reduces the impact of the boiler on the power grid during operation. The furnace body electric control cabinet is discrete, which avoids the service life of electrical components due to thermal aging, no noise, no pollution, and high thermal efficiency. The boiler body adopts high-quality and efficient insulation materials, and heat loss is small.

Reliability

①The boiler body is backed by argon arc welding, and the cover is manually welded, and has been strictly inspected by X-ray flaw detection.
②The boiler uses steel materials, which are selected in strict accordance with the manufacturing standards.
③Boiler accessories are selected from domestic and foreign high-quality products, and have been tested by the boiler to ensure the long-term normal operation of the boiler.

kekaox

Advantages & Disadvantages

Advantages and disadvantages of electric heating steam boiler

1. The boiler adopts electric heating tube to directly heat to produce steam, and the equipment is easy to operate.
2. Electric heating boilers consume a lot of power (a ton of steam highway consumes more than 700kw per hour), so the operating cost is relatively high and the requirements for supporting power equipment are relatively high, so the evaporation of electric heating boilers is relatively small .

1614753271(1)
1614753271

Technical Parameter

Model

WDR0.3

WDR0.5

WDR1

WDR1.5

WDR2

WDR3

WDR4

Capacity(t/h)

0.3

0.5

1

1.5

2

3

4

Steam pressure(Mpa)

0.7/1.0/1.25

Steam Temperature(℃)

174/183/194

Efficiency

98%

Power source

380V/50Hz    440V/60Hz

Weight (kg)

850

1200

1500

1600

2100

2500

3100

Dimension(m)

1.7*1.4*1.6

2.0*1.5*1.7

2.3*1.5*1.7

2.8*1.5*1.7

2.8*1.6*1.9

2.8*1.7*2.0

2.8*2.0*2.2